Flash Insight
ColdFire Ezport
Help

Help for devices of the ColdFire V2 Family that support the EzPort programming interface.

NOTE: Not all ColdFire devices support the EzPort interface. Please consult ColdFire Family documentation to be sure this programmer is the one you want.

NOTE: Not all ColdFire devices that provide the EzPort interface are supported by this programmer. Please verify that the device you want to program is in the Configuration Device list.

Table of Contents

Note: Where behaviour is provided by the Flash Insight application instead of by the installed programmer, links in the following table of contents will take you to the appropriate section of the main Flash Insight help page.

Glossary

Entries in this list are specific to the ColdFire EzPort programmer.

For general glossary entries see Flash Insight Help - Glossary.

Overview

For an overview of the Flash Insight product see Flash Insight Help - Overview.

The Flash Insight ColdFire EzPort programmer provides read, blank check, erase, program, verify, and run operations on ColdFire devices that support the EzPort interface.

Please note that not all ColdFire devices support the EzPort interface so be sure it's supported on the device you are using.

Please note that not all ColdFire devices which provide the EzPort interface are supported by this programmer. Please verify that the device you want to program is available in the device list.

The EzPort interface uses the SPI protocol, therefore one of the FTDI devices which support the MPSSE is used to interface to the ColdFire chip.

Electrical Interface

The ColdFire EzPort programmer uses FTDI's MPSSE engine to control the programming process. See Flash Insight Help - Overview for FTDI chips that implement the MPSSE engine.

ColdFire EzPort
Pin Name
FTDI
Pin Name
EZPCK/QSPI_CKxD0
EZPQ/QSPI_DOUTxD1
EZPD/QSPI_DINxD2
EZPCSxD6
RSTIxD4
RSTOxD5
Table 1 - ColdFire EzPort Pin List

System Components

Single Device Programmer

Configure

Figure 1 - Configure Dialog
Device

Select the device that you intend to program from the supplied list. Only devices that support the EzPort interface are listed.

Clock Frequency

Set the clock frequency for the main clock of the device. The supplied clock frequency is used to calculate the clock frequency used with the EzPort interface.

NOTE: The EzPort interface requires that the clock frequency not exceed a specific maximum and an incorrect clock frequency may damage the device.
Please exercise caution when setting this parameter.

Test (Button)

Click the Test button to perform a communications check with the ColdFire device once the interface has been configured.

ColdFire EzPort - Supported Device List

MCF5211MCF52211MCF52231MCF52252
MCF5212MCF52212MCF52232MCF52254
MCF5213MCF52213MCF52233MCF52255
MCF52100MCF52221MCF52234MCF52256
MCF52110MCF52223MCF52235MCF52258
MCF52210MCF52230MCF52236MCF52259